an ALT HomeSITE
CT-About Us

Index-PC

-m5 > -m4

CHROMTECH Specialists in Chromatography
- Fluid Transfer Products : & FOR All Your Laboratory Needs !
- Importers & Distributors in AUSTRALIA

Goole this CHROMTECH website

*

Chiral HPLC Columns

OR > mobile
& / or tablets

add >

“ -m4 ”
“ -m5 ”

to “URL”

Chromtech
MAIN Menus

re Covid-19 -m5

> ( Starters
AdminCategories

WOW  > FlipSlides >
ALT Home PagesOur External Sites )

Site Structure -m5)

SHOPPECart-2021+ Chromalytic/Chromtech Head

NAV INDEX

FIND-IT

> Or Ctrl-F this page

re Important Site UPGRADES

NEW FlipHML5 Site Catalog Library flip.chromalytic.net.au PC <  > Mobile ( & “responsive” ! > pinch&zoom / rotate ! )

FlipSITE 2016

Home 015

(simple) Home2014+

intro Detailed 013

 intro-FLIP WebSite 011

FlipHTML5 016+ (mobile compatible)

Chiral   HPLC

Applications

Chromtech - Chiral Handbook 40p PDF acrobat-but  FlipPAGE H’Book  Flip-A
PDF SEARCH works on text INDEX Only & NOT Pic chromatogrsms

What is it!
Separation of Optical isomers by HPLC.
Often the critical moities in biologically active materials whether in bioscience
or pharmaceuticals.
This complex “mirror image” molecular separation is often given scant recognition
by researchers primarily due to the difficulty in separating and analysing such
raecemic mixtures.
Let alone the difficulties of separating and purifing on a Preparative scale.

Chromtech chiral HPLC-columns for direct resolution of enantiomers
 - comprise 3 basic types

  • CHIRAL-AGP ( USP chiral column L41 )

    The CHIRAL-AGP column has extremely broad applicability.
    As can be seen from the applications a very large number of basic, acidic and
    nonprotolytic drugs and related compounds have been separated into enantiomers.
    The columns resolve chiral compounds containing primary-, secondary- or tertiary amino
    groups or quarternary ammonium groups, as well as chiral compounds containing
    carboxylic acid functions or weaker acidic groups as well as chiral nonprotolytes
     like alcohols, amides, sulphoxides, esters etc.
  • CHIRAL-CBH

    Cellobiohydrolase (CBH) is a very stable enzyme, which has been immobilized onto
     5 micrometer spherical silica particles. This is a reversed-phase column, used for
     the direct separation of enantiomers. The column is preferantially used for the separation
    of enantiomers of basic drugs from many compound classes.
     CHIRAL-CBH separates preferentially compounds containing one or more basic nitrogen
     together with one or more hydrogen accepting or hydrogen donating groups (alcohol, phenol, carbonyl, amide, ether, sulphoxide, ester etc.)
  • CHIRAL-HSA

    The CHIRAL-HSA column is based on human serum albumin (HSA).
     The protein has been immobilized onto spherical 5 micrometer particles.
    Enantiomers of preferentially acidic compounds can be resolved directly, without derivatization.
    CHIRAL-HSA is especially suited for the resolution of weak and strong acids, zwitterionic
    and nonprotolytic compounds.
    However, basic compounds have also been resolved.

 Chiral Column
Complete List

Column Type

CHIRAL-

-DIM (mm)

Analytical

AGP
CBH
HSA

150.4
100.4
50.4
150.3
100.
50.3

Micro

AGP
CBH
HSA

150.2
100.2
50.2

Semiprep

AGP
CBH
HSA

150.10
100.10

Analytical Guard 2/pk

AGP
CBH
HSA

10.42
10.32
10.22

Guard Column Holder

for All

CH10.3

Guard Column Connector

 

CON2

Micro GC Connector

 

CON4

Column Dimensions

  • Inner diameters 2, 3, 4, and 10 mm
  • Lengths of 50, 100 and 150 mm.
  • Guards with length of 10 mm and the inner diameters 2, 3 and 4 mm are also available
ChiralColumn-Access

Chiral columns for LC/MS

Dimensions

CHIRAL-AGP

CHIRAL-CBH

CHIRAL-HSA

50x2.0 mm
100x2.0mm
150x2.0mm

AGP50.2
AGP100.2
AGP150.2

CBH50.2
CBH100.2
CBH150.2

HSA50.2
HSA100.2
HSA150.2

50x3.0mm
100x3.0mm
150x3.0mm

AGP50.3
AGP100.3
AGP150.3

CBH50.3
CBH100.3
CBH150.3

HSA50.3
HSA100.3
HSA150.3

50x4.0mm

AGP60.4

CBH50.4

HSA50.4

Extensive Application Notes are available . . . hundreds of separations often with huge “alpha” offering opportunies for
massive scale up in column load capacities

Application Areas
At pharmaceutical companies, hospitals, universities and chemical industry CHIRAL-CBH is used for the analysis of
enantiomeric purity and for bioanalysis.
An interesting and fast growing area is isolation of pure enantiomers on semipreparative columns.

Mobile Phases
The mobile phases are mixtures of phosphate or acetate buffers and organic solvents as 2-propanol or
acetonitrile containing 50mM disodium EDTA. The retention and the enantioselectivity can be regulated by changes in pH,
 buffer concentration and organic modifier (nature and concentration)
.

& > as a product preview to / from
Our detail PC Site(s)

U can still “ Pinch&Zoom / Screen rotate ”
on a
“decent” Mobile phone

FlipHTML5 A-Z Index

A-Z HTM Page Index

*All OUR Site > chromtech.net.au -Now part converted > Mobile - m4 (400px) and -m5 ( =m4+FlyOut Menu )

ChromalyticTechnology PtyLtd 1995-2019 : All rights reserved:
OEM Supplier : Trademarks, Patents. logos apply ! Copyright Copyright-

FIND-IT ! OR for More details !

do a GOOGLE SEARCH THIS Site ! - & to cut out that other Web “crap” !

*GOOGLE SEARCH
> 1000px PC Results

the Web "Ask" chromtech.net.au
 

FIND-IT

> Or Ctrl-F this page