Filtration Accessories
 Filtration Hints

Vac-u-Fill Bottles PDF
VacuCap fast Filtration(PALL)
FastCap(Nalgene)

Liquid Dispensers
DoibleCheckValve Dispenser Syringe
Syringe Pump

Hand Vacuum Pump

Selection of Filter Media : by size
Flow propl to (Diam) sqrd

0.45um : 0.22um 
1.00 : 0.25 x speed

Syringe Filter : max Pressure 72psi (PP body )

Membrane Filter

Pre Filter : protects main filter from blocking extends lifetime and can improve speed

use coarser Glass Fibre

some have Class Fibre
Multi-Layer

on top of main filter

Relative speed based on
-   Surface Area of  Pore Size um

13 : 25 : 33mm;(50mm 90mm
0.27:1.0:1.75:4.0, 1.3 x speed

at same Pore Size um
& samemembrane material

 

-   Liquid Temperature

+20degC

~2x the spped 1/2 the viscosity

DON”T exceed membrane or filter holder max use Temp - generally 65degC MAX BUT CHECK !

Measured

Syringe Pump : Olive Oil 25C
30psi (PressGauge)
 20ml 19mmID Syringe
 0.5sqin >1.0ml/min
0.45um PVDF

50ml syringe 29mmID
> 2.3ml/min

 

Vacuum vs Pressure
0.45um PVDF

HandPump Vacuum 350mm = -7.0psi max developed Vac Flask Filtration
Syringe Filter 25mmD
Thumb Force ~10lb max
= 20psi ( but RSI problems ???)

47mm




25mm

47mm MF Calculated
Flow=0,66ml/min x
{ 47/25 }sqd = x 3.5
-= 2.30ml/min
Measured 20ml/6.0min =
3.3ml/min

 

Olive Oil

Viscosity
43cps 37C
24cps 54C

Flow is  proportionall to
1/ viscosity

heating speeds up flow
approx x2
for every +20degC

PROBLEMS ?

OK ! heat to help dissolve sample into “solvent” matrix
generally let mix cool before filtration to below << 65deg C

On-Cooling the sample itself can crystallise out and completely block the filter membrane and even the Glass Frit or support base of the filter holder

Membrane Filter and Filter Holder

Max Temp

Check the MAX Temperature use for each !

HEATERKIT
FiltrationEquip
SyringeDispenser-10ml
MityVac
NE300-Heater

Glass Filtration Equipment

Syringe Pump + Barrel heater

Syringe Dispenser

 250mmHg Vac

use with Syringe Filter 0.45um first run; 2nd run 0.22um for extra sterility

Oils (???) :
“Thin” Oils or Aqueous-based

Oils :  60ccSyringe 0.45um SF
Syringe Heater @ 55degC

10ml Only Extra leverage helps
Thin Oils or Solvents/Aqueous Based

Motorised pump run continuosly
0.45um 1ml/min
Use internal collection Test Tube

0.45um 25mm > 5ml/min
New 33mm SFs 1.75x faster 8cc/min
Heat to 55degC 2x faster 16cc/Min

2-way valve can be problematic with sticky oils ???

Vacu-Fill

Vac-U-Fill PDF acrobat
250mmHG
0.2um /  0.45um 47mm Membrane
1ml/min
new 90mm Diam 500ml/500ml
500ml/1000ml
Reservoir Bottles (spares)
250ml VFP250
500ml VFP500
1000ml VFP1000

Oils : some tend to soften polystyrene containers
- can crack or tend to “implode”/squash under Vac

VacuCap FastCAP Bottle-Top Filtration
How to . . . acrobat

for “OILS” > the BEST
Filtration Answer

for High Speed / thru’put
PES preferred for “polyester” Oils

Olive Oil; Canola, Palm oil, Cottonseed
- all approx the same viscosity
at 25degC 40-60cps at 25C
20-25cps at 55C

multi-Layer SF and pre-filters help
preserver main and can improve flow

Vac-U-Fill preferred for aqueous based mixes, more polar solvents

for auto-filling from sample reservoir - fast for thin low viscosity liquids

BTD

for thin aqueous Solutions
- Syringe Filter on Outlet of BTD
- Auto-filling
- extra pressure can be applied by palm of hand to increase speed
- with CARE as device is more delicate

Hand VAC Pump
- OK for quick filtration
- a leak-free system is necessary
- can be a bit tedious
250mm Vac
but 350 typical observed

ALL filters tend to block up depending on particulates that actually block the filter pores
- use of coarser pre-filter (glass Fibre) helps speed and the total sample throughput
for best results - match the polarity of the Membrane material with the polarity of the liquid
hydrophillic          :        PES      >          Nylon      >             PVDF       >            PTFE  Hydrophobic
                                               Water-based      polar solvents       polyester Oils         Hydrocarbon-based Oils
these are but generalisations - & it’s very much “trial and error” for each application
PES : OK for medium polarity OIls; eg grapeseed etc
Plastic (Bottle-Top) Filters / Syringes >avoid use of strong solvents
eg acetone > even ethanol is suspect And/Or use of too high as vacuum 200mmHG MAX is OK
even glass bottles run the risk of imploding . . . at higher Vacuum !

VacuCap-HP
VacuCap-2

use with Hand Vacuum Pump MityVac 12-MV8010

use with Motorised Vacuum Pump VPJ0332

VacuCap 90
90mm Diam Cap

VC-4621

0.1um for critical sterilisation

$375

10-pk

VC-4622

0.2umfor sterilisation

$350$440.00

Sterile / Fast

VC-4624

0.45um

$350

1-5Liter volumes . . . Simple Glassware Accessory use

The VacuCap Filter is used for sterilization or clarification of a wide variety of fluids.  use for cell culture and serum-containing media liquids

  • have a Supor (hydrophilic PES polyethersulfone) membrane which provides fast flow rates.
  • can draw directly from mix vessel and filters directly into the desired containers, minimizing transfer steps.
    accepts a variety of collection vessels.
  • VacuCap 90 Filter which is designed for volumes of 1–5L
  • have built-in prefilter that increases throughput of viscous or particulate solutions, such as serum-containing media.
  • Polyester membrane support. Acrylic housing.
  • VacuCap Filters are Sterile.
  • come with one piece of tubing per ten filter devices.
    The feedline accessory kit includes tubing and a glass sinker.

PES FastCAP 0.22um 90mm 
#298-9020 >
Now from Thermo
& supplied “sterile” packed

VacuCap-1

Nalgene FastCap Bottle Filter - Nalgene 298-9020 > & from Thermo

The Nalgene Fastcap Filter works on any bottle that has a neck opening of up to 53mm. The Nalgene FastCap Filter eliminates the need to use threaded glass media bottles.

Place a Nalgene FastCap filter on bottle mouth, attach a vacuum line to the larger center vaccum hose link and your liquid media tube to the smaller tube link and start filtering.

The Nalgene FastCap. . .

  • filters up to 5 liters of liquid.
  • Housing is blue polystyrene; the 90mm filter is made of PES (polyetheresulfone)
  • with a 0.2um pore diameter.. . . for sterility
    use with a disposable 47mm Membrane Filter where necessary
  • Each  filter is packaged in individual hermetically sealed plastic bags.
  • Nalgene FastCap filters are STERILE (gamma radiation sterilized).
     Nalgene
  • FastCap filters are sold in individual units or a case of 10 $440- per 10-pk
Nalgene-FastCap

VacuCap & Fast Cap are very similar in principle ( supply and demand determine Supplier and Chromtech Stock at any time)
Accessory Glassware(GL-45 Bottles/Fittings/Tubing) also available form Chromalytic - Enquire! . . . see Glassware ?

Syringe-Dispensing
DoubleCheckValve
Syr-DCVDispenser

Double CheckValve Dispenser

ReUsable_BTFilter
refillable BTD

Other Filtration Devices

Venting Filters
Capsule Filters

ASK !
for detals

ReUsable Filter Holder

IDEAL : Use as a pre-Filter for
Thermo FAST Cap System
Glass Fibre 0.6, 1.7um as deemed necessary
(Order Membrane Disc  separately)
ASK for FastCap PreFilter Kit ( luer tube connectors)

NOW! Full integration >
Price database into FlipPAGE format . . .
$$$ vs Cat.#
1   partial ~1000 more popular items open
CT mini-SITE . . . mobile site
2   ALL Main Suppliers Current Prices may require UPDATING due to XRs etc
NEW SHOPPE via www.chromalytic.net.au

Our Policy / Strategy
No! . . .  we don’t “muck around”
we DON’T have time for
“twitter and tweats” NOR ANY of  that Facebook “crap”

AND
. . . NOR are We . . .traditional” or
 “used cr “Sales-people” type
. . . but MORE technically orientated !

So WE . . . -   DON’T “Door Knock”
-   make “scam” calls, use "stooges"”
 tele-marketing methods
 or chain e-mails
-   NOR Waste YOUR valuable time
 . . . but . . . IF YOU WANT US ?
We are HERE !. . . have “targeted” tech information and analytical Chemistry products AND Solutions  . . .  >  just for You !

YES! . . .
We are here to
actuall TRY & help you
 !the proof !.
 . . EVEN our
direct competitors
 “USE” Us !

NEW 2015  HTML5 SHOP Site
New HTML5 improve HTML comapabilirt with AApple MAC, IPAD?Androids - but NO Flash

FlipShop SHOPPE

mini-site CHROMTECH

Copyright Copyright-Chromalytic Technology Pty Ltd 1995-2015+ : All rights reserved:  Supplier : Trademarks, Patents logos apply

this Website - best viewed in > ~1300px PC screen size with some APPLE MAC compatibility

 MobileSite  . for “MickeyMouse” phones

Chromtech Website > Chromalyic 2015+

more Filtration Hints

FlipPAGE CHROMTECH SUPPLIER Product List

HTML5 FAST SHOPPE here >

HTML5  -  NEW SHOPPE

HTML5  new

NEW 2027 Site Overview
www.chromtech-AUS.com

Parent Level

[Whats Chromatography]
[Restek Chromatography]
[GC Accessories]
[Restek Sections-Products]
[Chromatography Tubing]
[Chromatography Fittings]
[Ferrules]
[Instrumentation Valves]
[Filtration Accessories]
[GC Columns]
[HPLC Columns]
[LC Columns]
[HPLC Accessories]
[Valves-Instrumentation]
[Detectors-GC]

Current Level

more Filtration Hints

Child Level

[index]
 
TEXT SEARCH Site ONLY from the CLouds FAST !
goole this website

 Then Ctrl F to
* SEARCH TEXT 
this Page

Chromtechs' Overall Site NAVIGATION
“Site” Overview more
Current /Flip/ DIR /PDF2/ DIR

our "other" SITES
index
Home CHROMTECH 2016
www.chromalytic.net.au
Mobile-(mini)Site
NEW2017 INTRO Site
www.chromtech-aus.com/
old(er) PC FLASH Slides
Flash-Flip Catalogs
Flash-HTM Pages
Site ADMIN
How to Place an Order
Information
FAQs-OurSite
CT-AUD Prices
Freight Charges
Trading Terms
Disclaimer-10
SEARCH
.
SUPPLIER
SRI GCs
RESTEK Chromatography
Instrumentation-VICIValco
VICI-Jour-NewProducts
PlasticFittings-VALUEPLASTICS
COntact
NUTECH Air Monitoring
GasStandards-MESA
NEW ERA Syringe Pumps
Membrane Solutions
DET TID GC Detectors
PlasmaTek-Gas Analysis
ultraFAST GC
.
Product CATAGORIES
GC Columns
Packed GC Columns
Chiral HPLC Columns
HPLC Columns
LC Columns
HPLC Accessories
Pharma Vial Products
Instrumentation Valves
PeakSimple DataSystem
Chromatography Tubing
Chromatography Fittings
Ferrules
Vials-Syringes 10
Glass Vials-Bottles
MS Sample Vials
Syringes
Syringe Pumps
Instrumentation Valves
Filtration Accessories
Fluid Transfer
CHEMICAL Standards
RPC Silcosteel Treatment
HPLC Detector Lamps 09
Air Monitoring
Gas Systems
.
SAMPLE PREP
Sample Prep
Filtration Products
Q-SEP Quechers
SPE-SamplePrep
MS-Syringe Filters
Membrane Filters
.
Literature - Technical
ADVantage News
Technical Notes
.
General LAB EQUIPMENT
BioBase
MRC LAB Products
PlasmaTek-Gas Analysis
LabGlass-Hardware
.
NEW HTML5 Site
HOME www.chromalytic.net.au
/html5_bookcases.htm
.
Summary DIR Listing
PDF Listing
/FlipPAGE/ Listing (older)
Flip HTML5 Listing
more see> chromalytic.net.au

PRODUCT LIST

> “main” Prices 

FlipBook-1 acrobat

Main Suppliers ONLY > ~30,000 Items > Current System Prices